来源 https://bit.ly/2XB4r8u
原文作者表示自己的第一颗SF 600用了三个礼拜故障
第二颗使用约莫一个礼拜又再一次故障
jonnyGURU (海盗PSU设计总监) 也在下面回复了这个讨论串
@jonnyGURU SF600 Gold also affected?
Yep.
That sounds like the problematic lot code range.
194448 to 201148 lot codes have been problematic (to say the least).
The lot code I specified, which is where your two PSUs fall, had a known
issue with the insulator between the diode and heatsink tearing causing the
diode to short against the heatsink.
SF600也受影响
至少 194448 ~ 201148 批号都有问题
之前狼大有翻译故障原因
推 wolflsi : 一次侧APFC二极管的绝缘导热垫出问题导致高压短路05/11 13:30
总监也在其他文章说明这不可能破坏电脑其他组件
http://www.jonnyguru.com/forums/showthread.php?17455-SF750-batch-failure/page5
Like I've already said in this thread, the failure is on the PFC diode.
There's no risk to damaging the rest of the PC's hardware.
附赠一个海盗PSU测试图片(?
http://jongerow.com/images/plugged-in.jpg